Categories Data Protector 5.5, Data Protector 5.5, Data Protector 6.0, Data Protector 6.11, Data Protector 6.21 Data Protector – 64bit.a errors onupdate 9 May If you get error below, run OS man omnidb 2. General device and media problems Cannot access exchanger control device on Windows SCSI device remains locked and session fails Device open problem Using unsupported SCSI HBAs/FC HBAs on Windows Library reconfiguration But I've got only some error mesagges after loading medium:[Major 90:54] Cannot open device ([21] The device is not ready.) The medium was unloaded and put to one of the slots

Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. Procedure to do that: Disable device polling in the system registry by completing one of the two steps below: a. You will probably have to consult the media.log to see if there is anything there explaining the issue further, also look up OS logs (System Events on Win, dmesg on Unix). Check for Library/NSR firmware issues.

90/54 Blood Pressure

Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small Covered by US Patent. ADIC/GRAU DAS library installation failed Problem Action ADIC/GRAU DAS library installation failed.

omnidbutil -readdb [ -mmdb Directory ] [ -cdb Directory ] Here of course the read is into the database, from the specified directories. You can recover the previous library configuration if you reuse the file with a list of hosts in your SAN environment and scan the hosts with sanconf again. Most versions of Data Protector also have an Administrators Guide. inet.log ->  All inet requests are logged here - this will reflect communications with clients.

Or did this start to grow significantly just shortly?   HTH, Andre.

0 0 05/02/14--12:09: Re: Backup too slow for a fresh install of DP 8.1 Contact us about this Calculator Make sure that all devices configured in Data Protector are updated since only “no-rewind on close” device files will work, other wise you may receive the following message: [Major] From: [email protected] Already a member? Scan the hosts in the cell: sanconf -list_devices mySAN.txt -hostsfile hosts.txt Configure your library using the saved configuration file: sanconf -configure mySAN.txt -library LibrarySerialNumberLibraryName [RoboticControlHostName] [DeviceTypeNumber] -hostsfile hosts.txt The previous successful

The library configuration remains only partially created. I have a P2000 connected to two Proliant servers forming a cluster of Windows and file services discharged. Am I right? 0 Kudos Reply Scott McIntosh_2 Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎04-05-2004 Join the community of 500,000 technology professionals and ask your questions.

Calculator

Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking click You can change the block size of the device. 90/54 Blood Pressure IMPORTANT: Adding or removing tape drivers from the system may cause an older driver .inf file to be re-read, which in turn can re-enable RSM polling. lic.log  ->  Lists licensing alerts HealthCheck.log  -> Log of health check results cleaning.log  ->  Log of tape cleaning Installed Clients -> /etc/opt/omni/server/cell/omni_info License File is located in /etc/opt/omni/cell/lic.dat Command Line Interface

SDP 6.0 DOES NOT.  -You can find that on the file system in paths similar to those noted in 2. You will find the location: BUS / Target ID / LUN which should correspond with the properties of the tape unit defined in DP (0:2:1C). You can imagine how iSCSI goes bonkers in such a situation. By the way, this structure is covered fairly well inthe CONCEPTS guide.

We are using version A.06.11 of HP Data Protector software for backing up our servers. I'm assuming Windows, but you didn't list your Cell Manager OS, so I'm guessing. It is highly recommended to stop any tape monitoring software running on the SAN. Not even it isn't possible to scan the volumes.

In the Kernel we have to set new tunable Kernel parameter: St_san_safe=1 When enabled, the tunable forces the stape driver to fail all opens to device files with out no-rewind-on-close option GRAU CAPs are not configured properly Problem Action GRAU CAPs are not configured properly. Registration on or use of this site constitutes acceptance of our Privacy Policy.

In case of a physically replaced SCSI tape drive located in a SCSI library, make sure that the omnirc option OB2MADETECTDRIVESWAP is set to 1 (Default).

Is tape drive Go to Solution 1 Participant SelfGovern LVL 20 Storage Software18 1 Comment LVL 20 Overall: Level 20 Storage Software 18 Message Active 1 day ago Accepted Solution SCSI cabling and termination of the olden days, or their modern offspring (FC interactions with other initiators in the zone, iSCSI hickups of all kinds etc. Related task Library reconfiguration failure Problem Action Configuration errors are reported during modification of an existing library configuration using the sanconf command after the device list file has been altered. A path in a multipath device is misconfigured.

in all the task,,, i got a Cannot opend device ([2] Cannot find the file)..like and answaer... However, LTO and DDS devices report data sets and groups, respectively, and not bytes. No net gain.  Q5. Apart from that, you are living well in the specs.

You physically replaced a SCSI tape drive located in a SCSI library. above.  -for example C:Program FilesOmniBackDocs  -SDP 5.5 Administrators guide can be found here: http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?lang=en&cc=us&taskId=101&prodClassId=-1&contentType=SupportManual&docIndexId=179911&prodTypeId=18964&prodSeriesId=3188924  -You can use the GUI, HELP, ONLINE DOCUMENTATION  -All versions of SDP have help topics. I keep getting the following message when I start my Translog Backups   [90:161] Cannot write filemark. ([5] Input/output error)   Does anyone know what this means?  This always occurs after Problems involving device SCSI addresses are explained in detail in Appendix B of the HP Data Protector Installation and Licensing Guide.

For that reason, you may elect to focus on obsolete filenames from one server at a time. Note 1: Enabling SCSI reserve/release is a 3 step operation. Drives "not ready" and media "Data Protector Foreign medi Contact us about this article I should add that the SCSI address of the drives keep changing.  I have the box "automatically The media in the drive is accessed by another application (typically monitoring software that uses the same device file). 2.

Update all the device drivers & Firmware for the Library / Drive used. 3. Should we change something in the zoning configuration or data protector to make the backup through SAN? Click Here to join Tek-Tips and talk with other members! Ensure that no other application is using this device.

On the OS/2 system within the GRAU library, edit the file /das/etc/config. By joining you are opting in to receive e-mail. For an up-to-date list of supported platforms, see the latest support matrices at http://support.openview.hp.com/selfsolve/manuals. Community Data Protector Practitioners Forum CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches

You can stop the this using the "HP Management Agent" in the Control Panel and checking the "disable Fibre Agent Tape Support" or using the following HP utility if you have