Home > Data Protector > Data Protector Cannot Connect To The Scm

Data Protector Cannot Connect To The Scm

Note : TEST.com is your domain name of Active Directory 4) Add this useraccount to be used by the installation service Now you should be able to Add clients through Cell this is what I was looking for Reply Anna Rosalina says: January 19, 2011 at 3:49 am hello, if my DP server was running on unix (*HP-UX) and i want to The company has as its foccus the development of systems and solutions to Health Care area (Hospitals, Clinics, etc.). All Rights Reserved.. have a peek here

Extra Côcos Côcos pelo Mundo Quero um Côco Postagens Atom Postagens Comentários Atom Comentários HOME | SEARCH | REGISTER RSS | MY ACCOUNT | EMBED RSS | SUPER RSS I'm not able to format, recycle, ... I did not modifed OB2_OLDMAIL_FORMAT, so message should be embedded whatever it means. Action Two solutions are available: Make the Windows system, on which you are installing the Cell Manager, part of a domain. https://community.hpe.com/t5/Data-Protector-Practitioners/SCM-error-while-installin-DP-agent/td-p/4437345

Code by Web Directory | Wordpress Themes | Wordpress Design. He misses his old home, at beach... Maybe if I read it a few times it will male sense. For details, see the omniinetpasswd command description in the HP Data Protector Command Line Interface Reference.

  • Many thanks!
  • Really friends.
  • Subscribe Enter your email address and receive notifications of new posts by email.
  • C:\Program Files\OmniBack\bin>omniinetpasswd.exe -add \dataprotector Please enter password:********** Please retype password:********** User '\dataprotector' was successfully added. 1234 C:\Program Files\OmniBack\bin>omniinetpasswd.exe -add \dataprotectorPlease enter password:**********Please retype password:**********User '\dataprotector' was successfully added.
  • check what does the client IP address and to what IP address the CM resolves for the client FQDN.

    0 0 08/22/14--22:06: Re: My problem between the two devices HP
  • Problem If you cancel the Data Protector installation while some components have been already installed, Data Protector does not unistall them.
  • Email check failed, please try again Sorry, your blog cannot share posts by email. %d bloggers like this: Thebraveadmin's Blog Computer and IT stuff Skip to content HomeAbout ← HP Data
  • Bernd Riegler Valued Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎08-22-2010 11:34 PM ‎08-22-2010 11:34 PM Re:

They just want you to recover as fast as you can. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking I still don't some time!Aspargus are nice...ExcluirResponderGuzma23 de janeiro de 2012 17:27Yes, or you can even restore in the same place, if the problem was only on data lose... The domain admin is configured on the inet service " omniinetpasswd -add dom\admin" but i have the same error.Please, somebody know the resolution?TKS 0 Kudos Reply RQGuimaraes Regular Visitor Options Mark

Like this:Like Loading... Para isso abra o Prompt de Comando como administrador e execute o seguinte comando para verificar se já existe tal usuário: C:\Program Files\OmniBack\bin>omniinetpasswd.exe -list Para adicionar um novo usuário ao serviço, I added these parameters to omnirc config file on the client. ("C:\ProgramData\OmniBack\omnirc")    OB2SHMEM_IPCGLOBAL=1    OB2BDANET=1     OB2BMANET=12. What we need to do now is to add a User with admin rights to the INET Service.

Or on the 2008 client to be installed? Proudly powered by WordPress Data Protector - Passion for Data Protection data-protector.org Downloads BRICK Whitepaper Impressum FAQ Video Tutorials Home » HowTo » Cannot connect to the SCM - omniinetpasswd Cannot Good Job. Problem When adding a new HP-UX client to a Data Protector cell, the following error message may be displayed: /tmp/omni_tmp/packet: you do not have the required permissions to perform this SD

Após isso pode tentar novamente a instalação do Client que deverá funcionar e ser concluída com sucesso! This Site If you would compare your current experience with the experience a year ago, how have your impressions changed? Browse to your installation server (most likely the cell-manager). omniinetpasswd -list
* [email protected]

(*) Installation Server is using this user's credentials during push installation.

Help Topic ID: Product: Topic Title: Feedback: skip to main | skip to sidebar Coqueiro Digital e Seus Cocôs Cibernéticos Porque nem todos os Cocôs são Verdes! navigate here Ricardo Gusmão Gusmão back to WPD, now known as Agfa HealthCare as Senior Database Administrator. Action Check if the inetd or xinetd service is running: HP-UX systems: ps -ef | grep inetd Linux systems: ps -ef | grep xinetd To start the service, run: You also need to ensure that you have a local host, loopback entry in the hosts file (/etc/hosts).

Email Address Recent CommentsGeorge on HPE Data Protector - Patch Bundle 9.08danielbraun on HPE Data Protector - Patch Bundle 9.08George on HPE Data Protector - Patch Bundle 9.08Frank on HPE Data This media have all expired data but Now I'd like to add it to DP again. and other operations on this media.  Can you suggest me to readd this media to my free pool?

0 0 08/25/14--12:40: Re: Email (SMTP) notifications Contact us about this article http://haywirerobotics.com/data-protector/data-protector-cannot-connect-to-inet.html Consultei a apostila do curso e descobri o seguinte: É necessário adicionar um Usuário com direitos administrativos ao serviço do INET.

What I understand is: i) I need an account with local admin rights on the target Windows machine I want to push the HP DP DA to ii) I have to Eventually I disabled the firewall on both machines, ensured the network connectivity between both systems could be properly established and if the user credentials are correct. O usuário estava cadastrado no AD.

For disk space requirements, see the HP Data Protector Product Announcements, Software Notes, and References.

Everything matched as expected! To finish execute this command to make with the Installation Server use the account added: omniinetpasswd.exe -inst_srv_user \ User '[domain]\[ad_user]' is configured to be used by Installation Server. And then you This user should have administrative permissions and – of course – this user should already be created in your AD. October 2016 HPE Data Protector - Patch Bundle 8.16 27.

During remote installation of a Data Protector client, Data Protector repeatedly asks for a valid username and password because administrator rights are required for the remote installation. Contact us about this article Bob,  Thanks for the tip of editing the cell_info file.   Now, when I try to reinstall the client to the same server, I am getting Does it work the same for you?   Kind regards, Jan

0 0 08/25/14--12:50: Re: Email (SMTP) notifications Contact us about this article My understanding is that sending the Notification http://haywirerobotics.com/data-protector/data-protector-cannot-connect-to-inet-for-getting-filesystem-list.html Hope this helps.

CommandLineException: The controller is not available at localhost:9999 The installation process cannot access various utilities because the PATH system environment variable does not contain the directory %SystemRoot%\system32. x8664 is for x64 windows systems 4. Thank you. Action Check your DNS or LMHOSTS file configuration or activate it.

start setup.exe 5. For further information RTFM HP Data Protector 6.11 CLI Reference on page 345. thanks Ramesh P says: March 24, 2011 at 2:55 pm The steps given in this like is correct and it worked for me. Quem impedia o feliz encontro dos dois?

continue wizard   after installation you should see your windows client under "clients" in dp gui.   i suggest you always check the support matrix for your dp version if the Thanks Reply Georges says: January 30, 2012 at 4:54 pm Not sure where I have to type this. Bookmark the permalink. Action Manually uninstall already installed components after you cancelled the installation.

The support experience has remained the same. Problem After installing the UNIX Cell Manager, when the Cell Manager is started, the following error is displayed: ERROR:Cannot start "omniinet" service, system error: [1053] Unknown error 1053. Reply Anna Rosalina says: January 31, 2011 at 11:26 am yes, i wanto to install a agent client on windows 2008 server. No insert permission on host.

Share Facebook Twitter Google + LinkedIn Tags Data Protector About Stefano Mereghetti Founder of Smeretech.com. To create a new user use the add command and provide the passwort. I then went to the server on which I wanted to install the DP agents and added the same domain user to the local administrators group.Once I did this I was Just download android best root apk for your smart phone to root it.

Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small