Home > Data Protector > Data Protector Cannot Load Exchanger Medium Incorrect Function

Data Protector Cannot Load Exchanger Medium Incorrect Function

The library msl6060 is shared by all servers, when i try to backup with the client tape drives in hpux i have the error.[90:63] Cannot load exchanger medium ([1] Incorrect function. I have used the cleaning tape to scan the drives with many times before. Response: DPWIN -OO273 core, DPWIN -OO223 cell, DPWIN -OO334 Disk Agent, DPWIN -OO289 Media AgentThere is a warning event " Inv. By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner have a peek here

The libraries/drives' FW is up-to-date and other L4 drives work fine scanning the exact same slot. You can use the command "uma" to check that: opt/omni/lbin>uma -ioctl dev/rac/cxtxdx (this path will get with devbra output)Note: brings you in the UMA prompt type "stat" to get a status Alejandro says: June 29, 2012 7:41 PM Thank you, four your help! RE: Cannot load exchanger medium (Target drive is busy.) pete91z (TechnicalUser) 24 Nov 05 09:03 do any other clients use the same device for backups? https://community.hpe.com/t5/Data-Protector-Practitioners/Cannot-load-exchanger-medium/td-p/4063628

Is the problem restricted to a single tape ?Have you physical inspected the library ?O/S here is ?media is LTO3 or other ?patch level ?any clues in any of the other other wise it is hardware issue or u patch level is not up to date thanks and regardsSajjad Sahir 0 Kudos Reply boje Regular Advisor Options Mark as New Bookmark Subscribe Can some one please help me?BRPatrik 0 Kudos Reply All Forum Topics Previous Topic Next Topic 11 REPLIES OldSchool Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS

User with that permission can generate Encryption Keys for the hardware Encryption and store them in Key Managment Server 2. Register now while it's still free! Join Us! *Tek-Tips's functionality depends on members receiving e-mail. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking

I had 5 jobs schedule for last night but none of them are being reflected in IDb

0 0 03/06/15--23:51: Re: Advanced Scheduler DP 9.02 Contact us about this article what kind of tapes are in the library / slot 1? 0 Kudos Reply boje Regular Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner cartridge" Invalid cartridge.I want to change all tapes and try again.Thanks a lot. 0 Kudos Reply Ricardo Ferreira Cunha Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight

Registration on or use of this site constitutes acceptance of our Privacy Policy. if your user is : you will only see Objects backed up with that Owner unless granted that Priviilege.

0 0 03/06/15--06:03: Re: Erase LTO tapes to make them worthless Drive indices should be 1 and 2, not 3 and 4. Option:"Automatically discover changed SCSI address" will be ignored.[Major] From: [email protected] "HP:SDLT600_1_n-dex-90" Time: 31-Aug-06 09:27:29[90:173] REQUEST SENSE call failed.

  • Share This One Response so far.
  • Ensure you try to load the tape into the drive from the frontpanel.
  • Go to Solution. 0 Kudos Reply All Forum Topics Previous Topic Next Topic 4 REPLIES Georges Esteves Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight
  • Couldn't find any proper Documentation on how to correctly built up a Cluster with DP9, only some stuff in install guide they obviously copied from ancient DP5 or 6 documentation and
  • By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner
  • Check if there is still a tape in the drive??
  • And you have disabled RSM?Thanks,ScottHP Support 1 Kudo Reply GIL_8 Occasional Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content

Here's Why Members Love Tek-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More... Then restart the failed Data Protector session. Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. Go to Solution. 280217.doc ‏26 KB 0 Kudos Reply All Forum Topics Previous Topic Next Topic 8 REPLIES Scott McIntosh_2 Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to

It contains an erase function and options to overwrite Tapes from start to end with selected patterns. navigate here Post a Comment NEXT PREV HOME DOAG 2016 TROUG TurkceOracle.com Powered by Blogger. And the tape in slot 1 is a Cleaning tape. In my case, I got the following error on MSL8096 while doing so:"ME: invalid cartridge - Code: 63".For sure, this has nothing to do with DP.

Since everything worked fine last week and have done so for the last years. Response: other LTO2 Question: patch level ? if so are they working ok? http://haywirerobotics.com/data-protector/data-protector-cannot-load-exchanger-medium-target-drive-is-busy.html Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum.Just copy and paste the BBCode HTML Markdown MediaWiki reStructuredText code below into your site. HP: OpenView Storage

Response: Win Server 2003Question :media is LTO3 or other ? Contact us about this article II looked at some lab cases, I did not find this error at all   x Cell manager certificate generation failed. After autoconfigured the drive.

Page Views - Copyright © Emre Baransel - Oracle Blog -Metrominimalist- Powered by Blogger - Designed by Johanes Djogan - Login with LinkedIN Or Log In Locally Email Password Remember Me

Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action. By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner But that should not make any difference. The drive index may be incorrect.

I do believe the HW causes the issue here, as the library itself reports it too, but I'm still not sure of where to find the cause and solution.Thanks!Niels. 0 Kudos Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Then i get this message right after it tries to load tape from slot1: "Cannot load exchanger medium (Incompatible medium installed.)"I have tried to replace the cleaning-tape but i get the this contact form THanks.Jason 1 person had this problem. 0 Kudos All Forum Topics Previous Topic Next Topic 9 REPLIES Eblyn Solis Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS

RE: Cannot load exchanger medium (Target drive is busy.) nath01 (TechnicalUser) (OP) 24 Nov 05 09:39 i think i have managed to get it to work now! Community Data Protector Practitioners Forum CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches Totally is 4 drives + robotic.Mappings looks like this:NSR1Port Map DisplayMap: FCP Port 0: Name 'Indexed'+--------++------+------+------+------+------------------------------------+| FC LUN || Prtl | Port | TYPE | STAT | Protocol Specific Information |+--------++------+------+------+------+------------------------------------+| The only thing i have done is to upgrade CM to DP 6.11.