Neither do those opinions reflect those of other individuals affiliated with any entity with which I am affiliated nor those of the entities themselves. commandsit stops the system updating the sysprocplan The sysprocplan will optimize the procedure on the first time you call the procedure, after you update stats on tables or alter the table Click Here to join Tek-Tips and talk with other members! Read 20 Sep 10 - planetIDS.com - ITG analyst paper: Cost/Benefit case for IBM Informix as compared to Microsoft SQL Server... http://haywirerobotics.com/error-cannot/error-cannot-open-catalog-message-number-90.html

Lester Knutsen (IBM Champion) writes about database back up safety using "archecker"... Second, immediately after doing the table, update statistics on the stored procedures. Close Box Join Tek-Tips Today! Top Help "could not read system catalog (sysprocplan)" by Paul Watso » Fri, 31 Aug 2001 16:53:13 Run update statistics for all the procedures, or if you can identify the one http://www.tek-tips.com/viewthread.cfm?qid=678592

Read 01 Feb 13 - IBM Data Magazine - Are your database backups safe? Details about the SQL Exception !! 23:06:42.845 |19065,,,MTA,11,Thread=MtaMailDelivery-2; class=CsUnityMtaErrorWriter;Error Message=Cannot update system catalog (sysprocplan)., SQLState=IX000, ErrorCode=-312 (-312) 23:06:42.845 |19065,,,MTA,11,Thread=MtaMailDelivery-2; class=CsUnityMtaErrorWriter;!! Local fix Problem summary **************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server V8.0 using Common Event * * Infrastructure (CEI) with version 11.70 of * *

  1. You are concerned that a stored procedure recompile during the transaction will lock the record in sysprocplan for the entire transaction, and other calls to the stored procedure will fail because
  2. Advertisement dBforums Brief Subscribe to dBforums Brief to receive special offers from dBforums partners and sponsors Top Helpers healdem - 59 mark.b - 55 Pat Phelan - 54 ranman256 - 23
  3. Read 27 May 11 - IBM Data Management Magazine - IIUG user view: Big data, big time ( Series data, warehouse acceleration, and 4GLs )...
  4. Also you can increase the high water mark. > For the error in sysprocplan : > One of your output shows that you are getting lock contention also, which > means
  5. Read 9 Mar 11 - DBTA - Database Administration and the Goal of Diminishing Downtime...

I don't know what to do. Your application may be the one causing the recompile or it may be a victim. If neither of this works, check you db with oncheck -cI This is what I can think of...... Check the accompanying ISAM error code for more information.

Can anyone help me? You may try by setting the > > lock mode to wait 60. Read 22 Mar 12 - developerWorks - Optimizing Informix database access... Read 1 Aug 11 - IBM Data Management Magazine - IIUG user view: Happy 10th anniversary to IBM and Informix...

The time now is 15:06. Read 16 May 11 - Business Wire - HiT Software Announces DBMoto for Enterprise Integration, Adds Informix. I always get the following error message: Cannot read system catalog(sysprocplan) ISAM error: key value locked. As a workaround, i have to turn off the application > service,run > update stat and start back the application service.

SQL State: S1000 Native: -144 Message: [INTERSOLV][ODBC Informix driver][Informix]ISAM error: key value locked I'm am getting too a "long transaction error aborted" when I try to update the database statistics??. > Register now while it's still free! Registered users can view up to 200 bugs per month without a service contract. Read 2 Feb 11 - DBTAs - Informix 11.7 Flexible Grid Provides a Different Way of Looking at Database Servers...

Users :- 20 K Tui Load:- on 19400 users with 8 bomber. this content In Response To: SQL Error Code: -211 (CHEE KHUAN LEONG) This will happen when some session modifies a table that is referenced by some stored procedure. Learn More About Cisco Service Contracts Information For Small Business Midsize Business Service Provider Executives Industries Automotive Consumer Packaged Goods Education Energy Financial Services Government Healthcare Hospitality Life Sciences Manufacturing Materials Problem conclusion To prevent the error ¢â‚¬ “312: Cannot update system catalog (sysprocplan) ¢â‚¬ ½ the size of database space for the event s was increased.

What's wrong?? Read 13 Jan 12 - MC Press online - Informix Dynamic Server Entices New Users with Free Production Edition ... or if the error is from read : set isolation to dirty > read. > If neither of this works, check you db with oncheck -cI > This is what I weblink Anyway, it seems to me that this a non-fatal in nature, because it says "key value locked." You may retry, and see if the error has vanished, owing to removal of

What could be the problem?. All rights reserved. Log-based Change Data Capture...

Top Help "could not read system catalog (sysprocplan)" by Alvin EChmotor#3 » Tue, 04 Sep 2001 20:42:41 As you say, I have updated the statistics form all the procedures, but I'm

Read 19 May 10 - The New Blog Times - Misurare il consumo energetico: DEHEMS è pronto... What's wrong?? Thx Hi, This is a bug of version. Re: SQL Error Code: -211 (views: 1408)Art Kagel -- Monday, 23 March 2009, at 11:38 a.m. [ View Thread ] [ Post Response ] [ Return to Index ] [ Read

The optimizer will see it's got a current plan and forgo the reoptimization. SQL State: S1000 Native: -211 Message: [INTERSOLV][ODBC Informix driver][Informix]Cannot read system catalog (sysprocplan). These procedures will recompile themselves EVERY TIME they are executed. http://haywirerobotics.com/error-cannot/error-cannot-read-or-display-file.html We run update statistics every day.

If necessary, restore the database from backup and logical-log tapes.

Copyright Privacy Home Skip to content Skip to footer Worldwide [change] Log In Account Register My Cisco Cisco.com Worldwide Home Resources Join | Indeed Jobs | Advertise Copyright © 1998-2016 ENGINEERING.com, Inc. I'm running a payroll calculation aplication, and if I send the program from a client i dont have any problem, but when I launch the calculation from three or four clients, Read 2 Aug 12 - channelbiz - Oninit Group launches Pay Per Pulse cloud-based service...

Read 6 Feb 12 - PRLOG - Informix port delivers unlimited database scalability for popular SaaS application ... Quote:> For the long transactions: increase the number of logical logs you have in > the system. I have been setting the "lock level" to "ROW" for all these tables where I get the lock error, but the errors remains. Call Stack Trace of the Exception (reverse order)!! 23:06:42.845 |19065,,,MTA,11,Thread=MtaMailDelivery-2; class=CsUnityMtaErrorWriter;0 : java.lang.Thread.run(Thread.java:662) 23:06:42.845 |19065,,,MTA,11,Thread=MtaMailDelivery-2; class=CsUnityMtaErrorWriter;1 : com.cisco.unity.mta.CsUnityMtaMessageProcessingPool.run(CsUnityMtaMessageProcessingPool.java:210) Conditions: Started Load on cluster env.

Read 9 Apr 12 - Mastering Data Management - Upping the Informix Ante: Advanced Data Tools... Are you aComputer / IT professional?Join Tek-Tips Forums! Powered by vBulletinCopyright ©2000 - 2016, Jelsoft Enterprises Ltd.Forum Answers by - Gio~Logist - Vbulletin Solutions & Services Home Register New Posts Advertising Archive Privacy Statement Sitemap Top Hosting and Cloud Did you perform an "update statistics" on any table meanwhile?

Optimizing 9. SQL State: S1000 > Native: -144 > Message: [INTERSOLV][ODBC Informix driver][Informix]ISAM error: key value > locked > I'm am getting too a "long transaction error aborted" when I try to update Gustavo. By joining you are opting in to receive e-mail.

The memory could not be "read". Read 1 Mar 12 - IBM Data Management - Running Informix on Solid-State Drives.Speed Up Database Access...